Difference between revisions of "Building model"
From Testiwiki
(→Rationale: causal diagram added) |
(dependencies described) |
||
Line 9: | Line 9: | ||
==Answer== | ==Answer== | ||
− | For | + | For examples of model use, see [[Building stock in Kuopio]] and [[Climate policies and health in Kuopio]]. |
==Rationale== | ==Rationale== | ||
Line 102: | Line 102: | ||
cat("Saved ovariables buildings, heatingEnergy\n") | cat("Saved ovariables buildings, heatingEnergy\n") | ||
</rcode> | </rcode> | ||
+ | |||
+ | ===Dependencies=== | ||
+ | |||
+ | * [[Exposure to PM2.5 in Finland]] | ||
+ | * [[OpasnetUtils/Drafts]] | ||
+ | * [[Energy use of buildings]] | ||
+ | * Ovariables used or produced and example pages where they are used: | ||
+ | ** [[Building stock in Kuopio]] | ||
+ | *** buildingStock, # Current building stock | ||
+ | *** renovation, # Percentage of renovations per year | ||
+ | *** renovationShares, # Fraction of renovation type when renovation is done. | ||
+ | *** construction, # Construction rate in the future | ||
+ | *** constructionAreas, | ||
+ | *** buildingTypes, # A dummy variable to combine two different indices: Building and Building2 | ||
+ | *** heatingShares, # Heating types of current buildings | ||
+ | *** heatingSharesNew, # Heating types of the buildings in the future | ||
+ | *** buildings, | ||
+ | ** [[Energy use of buildings]] | ||
+ | *** energyUse, | ||
+ | *** efficienciesNew, # Energy efficiencies in the future | ||
+ | *** savingPotential, | ||
+ | ** [[Climate change policies and health in Kuopio]] | ||
+ | *** eventyear, # A dummy variable to combine time periods to numerical time axis. | ||
+ | *** efficiencies, # Energy efficiencies of current buildings | ||
+ | *** obsyear # Years for which observations are calculated. This requires timepoints function. | ||
+ | |||
==See also== | ==See also== | ||
− | * [[ | + | * [[Building stock in Kuopio]] |
* [[Building stock in Europe]] | * [[Building stock in Europe]] | ||
* [[Building data availability in Kuopio]] | * [[Building data availability in Kuopio]] |
Revision as of 03:25, 6 March 2014
This page is a method.
The page identifier is Op_en6289 |
---|
Moderator:Jouni (see all) |
Give your opinion to the peer rating of the content of this page. |
Upload data
|
Question
How to estimate the size of the building stock of a city, including heating properties, renovations etc? The situation is followed over time, and different policies can be implemented.
Answer
For examples of model use, see Building stock in Kuopio and Climate policies and health in Kuopio.
Rationale
Error creating thumbnail: Unable to save thumbnail to destination
Calculations
Dependencies
- Exposure to PM2.5 in Finland
- OpasnetUtils/Drafts
- Energy use of buildings
- Ovariables used or produced and example pages where they are used:
- Building stock in Kuopio
- buildingStock, # Current building stock
- renovation, # Percentage of renovations per year
- renovationShares, # Fraction of renovation type when renovation is done.
- construction, # Construction rate in the future
- constructionAreas,
- buildingTypes, # A dummy variable to combine two different indices: Building and Building2
- heatingShares, # Heating types of current buildings
- heatingSharesNew, # Heating types of the buildings in the future
- buildings,
- Energy use of buildings
- energyUse,
- efficienciesNew, # Energy efficiencies in the future
- savingPotential,
- Climate change policies and health in Kuopio
- eventyear, # A dummy variable to combine time periods to numerical time axis.
- efficiencies, # Energy efficiencies of current buildings
- obsyear # Years for which observations are calculated. This requires timepoints function.
- Building stock in Kuopio
See also