Difference between revisions of "Building stock in Helsinki"

From Testiwiki
Jump to: navigation, search
(Building stock)
m (Answer)
 
(79 intermediate revisions by 6 users not shown)
Line 1: Line 1:
 +
<noinclude>
 
[[Category:Helsinki]]
 
[[Category:Helsinki]]
 
[[Category:Buildings]]
 
[[Category:Buildings]]
 
{{variable|moderator=Jouni}}
 
{{variable|moderator=Jouni}}
 +
:''During [[Decision analysis and risk management 2015]] course, this page was used to collect student contributions. To see them, look at [http://en.opasnet.org/en-opwiki/index.php?title=Building_stock_in_Helsinki&oldid=37151 an archived version]. The page has since been updated for its main use. Data in the archived tables was moved: [[Helsinki energy consumption#Energy parametres of buildings| Table 2. Energy parametres of buildings]], [[Helsinki energy consumption#Energy demand|Table 4. Energy sinks]], [[Helsinki energy consumption#Energy demand| Table 5. Changes in energy efficiency]], [[Helsinki energy consumption#Heating parametres of buildings|Table 6. Important energy parametres]]. Tables 3, 7, and 8 did not contain data and were removed.
 +
</noinclude>
  
 
== Question ==
 
== Question ==
  
What is the building stock in Helsinki and what are some of the key parameters of energy use?
+
What is the building stock in Helsinki and its projected future?
  
 
== Answer ==
 
== Answer ==
  
=== Data ===
+
<gallery widths="400px" heights="350px">
 +
File:Current building stock in Helsinki.png|Current building stock in Helsinki by heating type.
 +
File:Building stock in Helsinki by heating.png|Projected building stock based on 2015 data and urban plans.
 +
</gallery>
  
* [[Unit heat consumption of buildings in Finland]]
+
<rcode embed=1 graphics=1>
* http://era17.fi/wp-content/uploads/2010/10/sitran_selvityksia_39.pdf page 25
+
## This code is Op_en7115/ on page [[Building stock in Helsinki]].
* http://www.teeparannus.fi/attachements/2010-12-21T11-54-1114846.pdf pages 8-9, also 40-45
+
 
* http://www.vtt.fi/inf/pdf/tiedotteet/2007/T2377.pdf page 20-21, also 30, 80
+
library(OpasnetUtils)
* [[Heating consumption of buildings]]
+
library(ggplot2)
 +
 
 +
objects.latest("Op_en7115", code_name = "stockBuildings")
 +
 
 +
stockBuildings <- EvalOutput(stockBuildings)
 +
 
 +
ggplot(stockBuildings@output, aes(x = Time, weight = stockBuildingsResult, fill = Heating)) +
 +
geom_bar(binwidth = 5) + theme_gray(base_size = 24) +
 +
labs(
 +
title = "Current building stock (floor area) by heating type \n and year of construction",
 +
x = "Construction year",
 +
y = expression("Floor area ( "*m^2*" )"))
 +
 
 +
ggplot(stockBuildings@output, aes(x = Time, weight = stockBuildingsResult, fill = Building)) +
 +
geom_bar(binwidth = 5) + theme_gray(base_size = 24) +
 +
labs(
 +
title = "Current building stock (floor area) by building type \n and year of construction",
 +
x = "Construction year",
 +
y = expression("Floor area ( "*m^2*" )"))
 +
 
 +
</rcode>
 +
 
 +
== Rationale ==
 +
 
 +
This part contains the data needed for calculations about the building stock in Helsinki. It shows the different building and heating types in Helsinki, and how much and what kind of renovations are done for the existing building stock in a year, including how much and how old building stock is demolished. This data is used in further calculations in the model.
 +
 
 +
There is also some other important data that wasn't used in the model's calculations. These include more accurate renovation statistics for residential buildings, U-value changes for renovations and thermal transmittance of different parts of residential buildings. This data is found under [[Building stock in Helsinki#Data not used|Data not used]].
 +
 
 +
=== Building stock ===
 +
 
 +
'''These tables are based on FACTA database classifications and their interpretation for assessments.
 +
This data is used for modelling. The data is large and can be seen from [http://en.opasnet.org/w/Special:Opasnet_Base?id=Op_en7115.stock_details the Opasnet Base]. Technical parts on this page are hidden for readability. Building types should match [[Energy use of buildings#Baseline energy consumption]].
 +
 
 +
{{hidden|
 +
 
 +
<t2b name="Building types" index="Building types in Facta" obs="Building" desc="Number of the class" unit="-">
 +
Yhden asunnon talot|Detached and semi-detached houses|11
 +
Kahden asunnon talot|Detached and semi-detached houses|12
 +
Muut erilliset pientalot|Detached and semi-detached houses|13
 +
Rivitalot|Attached houses|21
 +
Ketjutalot|Attached houses|22
 +
Luhtitalot|Blocks of flats|32
 +
Muut asuinkerrostalot|Blocks of flats|39
 +
Vapaa-ajan asuinrakennukset|Free-time residential buildings|41
 +
Myymälähallit|Commercial|111
 +
Liike- ja tavaratalot, kauppakeskukset|Commercial|112
 +
Myymälärakennukset|Commercial|119
 +
Hotellit, motellit, matkustajakodit, kylpylähotellit|Commercial|121
 +
Loma-, lepo- ja virkistyskodit|Commercial|123
 +
Vuokrattavat lomamökit ja osakkeet (liiketoiminnallisesti)|Commercial|124
 +
Muut majoitusliikerakennukset|Commercial|129
 +
Asuntolat, vanhusten palvelutalot, asuntolahotellit|Commercial|131
 +
Muut asuntolarakennukset|Commercial|139
 +
Ravintolat, ruokalat ja baarit|Commercial|141
 +
Toimistorakennukset|Offices|15
 +
Toimistorakennukset|Offices|151
 +
Rautatie- ja linja-autoasemat, lento- ja satamaterminaalit|Transport and communications buildings|161
 +
Kulkuneuvojen suoja- ja huoltorakennukset|Transport and communications buildings|162
 +
Pysäköintitalot|Transport and communications buildings|163
 +
Tietoliikenteen rakennukset|Transport and communications buildings|164
 +
Muut liikenteen rakennukset|Transport and communications buildings|169
 +
Keskussairaalat|Buildings for institutional care|211
 +
Muut sairaalat|Buildings for institutional care|213
 +
Terveyskeskukset|Buildings for institutional care|214
 +
Terveydenhuollon erityislaitokset|Buildings for institutional care|215
 +
Muut terveydenhuoltorakennukset|Buildings for institutional care|219
 +
Vanhainkodit|Buildings for institutional care|221
 +
Lasten- ja koulukodit|Buildings for institutional care|222
 +
Kehitysvammaisten hoitolaitokset|Buildings for institutional care|223
 +
Muut huoltolaitosrakennukset|Buildings for institutional care|229
 +
Lasten päiväkodit|Buildings for institutional care|231
 +
Muualla luokittelemattomat sosiaalitoimen rakennukset|Buildings for institutional care|239
 +
Vankilat|Buildings for institutional care|241
 +
Teatterit, konsertti- ja kongressitalot, oopperat|Assembly buildings|311
 +
Elokuvateatterit|Assembly buildings|312
 +
Kirjastot ja arkistot|Assembly buildings|322
 +
Museot ja taidegalleriat|Assembly buildings|323
 +
Näyttelyhallit|Assembly buildings|324
 +
Seurain-, nuoriso- yms. talot|Assembly buildings|331
 +
Kirkot, kappelit, luostarit, rukoushuoneet|Assembly buildings|341
 +
Seurakuntatalot|Assembly buildings|342
 +
Muut uskonnollisten yhteisöjen rakennukset|Assembly buildings|349
 +
Jäähallit|Assembly buildings|351
 +
Uimahallit|Assembly buildings|352
 +
Tennis-, squash- ja sulkapallohallit|Assembly buildings|353
 +
Monitoimihallit ja muut urheiluhallit|Assembly buildings|354
 +
Muut urheilu- ja kuntoilurakennukset|Assembly buildings|359
 +
Muut kokoontumisrakennukset|Assembly buildings|369
 +
Peruskoulut, lukiot ja muut|Educational buildings|511
 +
Ammatillisten oppilaitosten rakennukset|Educational buildings|521
 +
Korkeakoulurakennukset|Educational buildings|531
 +
Tutkimuslaitosrakennukset|Educational buildings|532
 +
Järjestöjen, liittojen, työnantajien yms. opetusrakennukset|Educational buildings|541
 +
Muualla luokittelemattomat opetusrakennukset|Educational buildings|549
 +
Voimalaitosrakennukset|Industrial buildings|611
 +
Yhdyskuntatekniikan rakennukset|Industrial buildings|613
 +
Teollisuushallit|Industrial buildings|691
 +
Teollisuus- ja pienteollisuustalot|Industrial buildings|692
 +
Muut teollisuuden tuotantorakennukset|Industrial buildings|699
 +
Teollisuusvarastot|Warehouses|711
 +
Kauppavarastot|Warehouses|712
 +
Muut varastorakennukset|Warehouses|719
 +
Paloasemat|Fire fighting and rescue service buildings|721
 +
Väestönsuojat|Fire fighting and rescue service buildings|722
 +
Muut palo- ja pelastustoimen rakennukset|Fire fighting and rescue service buildings|729
 +
Navetat, sikalat, kanalat yms.|Agricultural buildings|811
 +
Eläinsuojat, ravihevostallit, maneesit|Agricultural buildings|819
 +
Viljankuivaamot ja viljan säilytysrakennukset|Agricultural buildings|891
 +
Kasvihuoneet|Agricultural buildings|892
 +
Turkistarhat|Agricultural buildings|893
 +
Muut maa-, metsä- ja kalatalouden rakennukset|Agricultural buildings|899
 +
Saunarakennukset|Other buildings|931
 +
Talousrakennukset|Other buildings|941
 +
Muualla luokittelemattomat rakennukset|Other buildings|999
 +
Ammatilliset oppilaitokset|Educational buildings|
 +
Kirjastot|Other buildings|
 +
Lastenkodit, koulukodit|Other buildings|
 +
Loma- lepo- ja virkistyskodit|Other buildings|
 +
Monitoimi- ja muut urheiluhallit|Other buildings|
 +
Museot, taidegalleriat|Assembly buildings|
 +
Muut kerrostalot|Blocks of flats|
 +
Muut majoitusrakennukset|Commercial|
 +
Muut terveydenhoitorakennukset|Buildings for institutional care|
 +
Terveydenhoidon erityislaitokset (mm. kuntoutuslaitokset)|Buildings for institutional care|
 +
Vapaa-ajan asunnot|Free-time residential buildings|
 +
Viljankuivaamot ja viljan säilytysrakennukset, siilot|Warehouses|
 +
</t2b>
 +
 
 +
{{comment|# |Viimeiset 12 riviä (ilman numeroa) ovat tyyppejä jotka ovat datassa (tai ainakin vanhassa taulukossa) mutta puuttuvat Sonjan luokittelusta.|--[[User:Jouni|Jouni]] ([[User talk:Jouni|talk]]) 12:57, 24 August 2015 (UTC)}}
 +
 
 +
For residential buildings (classes A and B) the classification is kept more detailed than for other buildings. This is because residential buildings are the biggest energy consumers in Helsinki and different classes of residential buildings are examined separately.<br />
 +
Reference for the classification: http://www.stat.fi/meta/luokitukset/rakennus/001-1994/koko_luokitus.html
  
==== Building stock ====
+
<t2b name="Heating types" index="Heating types in Facta" obs="Heating" unit="-">
 +
|Other
 +
Kauko- tai aluelämpö|District heating
 +
Kevyt polttoöljy|Light oil
 +
Kivihiili, koksi tms.|Coal
 +
Maalämpö tms.|Geothermal
 +
Puu|Wood
 +
Raskas polttoöljy|Fuel oil
 +
Sähkö|Electricity
 +
Kaasu|Gas
 +
Muu|Other
 +
</t2b>
  
 
The structures of the tables are based on CyPT Excel file N:\YMAL\Projects\ilmastotiekartta\Helsinki Data Input Template - Building Data.xlsx.
 
The structures of the tables are based on CyPT Excel file N:\YMAL\Projects\ilmastotiekartta\Helsinki Data Input Template - Building Data.xlsx.
 +
}}
 +
 +
<rcode name="stockBuildings" label="Initiate stockBuildings (developers only)" embed=1 store=1>
 +
library(OpasnetUtils)
 +
library(ggplot2)
 +
 +
# [[Building stock in Helsinki]], building stock, locations by city area (in A Finnish coordinate system)
 +
#stockBuildings <- Ovariable("stockBuildings", ddata = "Op_en7115.stock_details")
 +
#colnames(stockBuildings@data)[colnames(stockBuildings@data) == "Built"] <- "Time"
 +
#colnames(stockBuildings@data)[colnames(stockBuildings@data) == "Postal code"] <- "City_area"
 +
 +
# [[Building stock in Helsinki]]
 +
dat <- opbase.data("Op_en7115.stock_details")[ , c(
 +
# "Rakennus ID",
 +
"Sijainti",
 +
"Valmistumisaika",
 +
# "Julkisivumateriaali",
 +
"Käyttötarkoitus",
 +
# "Lämmitystapa",
 +
"Polttoaine",
 +
# "Rakennusaine",
 +
# "Varusteena koneellinen ilmanvaihto",
 +
# "Perusparannus",
 +
# "Kunta rakennuttajana",
 +
# "Energiatehokkuusluokka",
 +
# "Varusteena aurinkopaneeli",
 +
"Tilavuus",
 +
"Kokonaisala",
 +
"Result" # Kerrosala m2
 +
)]
 +
 +
colnames(dat) <- c("City_area", "Time", "Building types in Facta", "Heating types in Facta", "Tilavuus", "Kokonaisala", "Kerrosala")
 +
dat$Time <- as.numeric(substring(dat$Time, nchar(as.character(dat$Time)) - 3))
 +
 +
#dat <- dat[dat$Time != 2015 , ] # This is used to compare numbers to 2014 statistics.
 +
 +
dat$Time <- as.numeric(as.character((cut(dat$Time, breaks = c(0, 1885 + 0:26*5), labels = as.character(1885 + 0:26*5)))))
 +
dat$Tilavuus <- as.numeric(as.character(dat$Tilavuus))
 +
dat$Kokonaisala <- as.numeric(as.character(dat$Kokonaisala))
 +
dat$Kerrosala <- as.numeric(as.character(dat$Kerrosala))
 +
 +
build <- tidy(opbase.data("Op_en7115.building_types"))
 +
colnames(build)[colnames(build) == "Result"] <- "Building"
 +
 +
heat <- tidy(opbase.data("Op_en7115.heating_types"))
 +
colnames(heat)[colnames(heat) == "Result"] <- "Heating"
 +
 +
######################
 +
# Korjaus
 +
########################
 +
temp <- as.character(heat$Heating)
 +
temp[temp == "District heating"]  <- "District"
 +
temp[temp == "Light oil"]  <- "Oil"
 +
temp[temp == "Fuel oil"]  <- "Oil"
 +
 +
heat$Heating <- temp
 +
########################################
 +
 +
dat <- merge(merge(dat, build), heat)#[c("City_area", "Time", "Building", "Heating", "stockBuildingsResult")]
 +
 +
dat$Kerrosala[is.na(dat$Kerrosala)] <- dat$Kokonaisala[is.na(dat$Kerrosala)] * 0.8 # If floor area is missing, estimate from total area.
 +
 +
cat("Kerrosala ilman 2015 (m^2)\n")
 +
oprint(aggregate(dat["Kerrosala"], by = dat["Building"], FUN = sum, na.rm = TRUE))
 +
cat("Kokonaisala ilman 2015 (m^2)\n")
 +
oprint(aggregate(dat["Kokonaisala"], by = dat["Building"], FUN = sum, na.rm = TRUE))
 +
cat("Tilavuus ilman 2015 (m^3)\n")
 +
oprint(aggregate(dat["Tilavuus"], by = dat["Building"], FUN = sum, na.rm = TRUE))
 +
 +
temp <- aggregate(dat["Kerrosala"], by = dat[c("Time", "Building", "Heating")], FUN =sum, na.rm = TRUE)
 +
colnames(temp)[colnames(temp) == "Kerrosala"] <- "stockBuildingsResult"
 +
 +
stockBuildings <- Ovariable("stockBuildings", data = temp)
 +
 +
objects.store(stockBuildings)
 +
cat("Ovariable stockBuildings stored.\n")
 +
</rcode>
 +
 +
=== Construction and demolition ===
 +
 +
It is assumed that construction occurs at a constant rate so that there is an increase of 42% in 2050 compared to 2013. Energy efficiency comes from [[Energy use of buildings]].
 +
 +
<rcode name="changeBuildings" label="Initiate changeBuildings (for developers only)" embed=1>
 +
# This code is Op_en7115/changeBuildings on page [[Building stock in Helsinki]]
 +
library(OpasnetUtils)
 +
 +
changeBuildings <- Ovariable("changeBuildings",
 +
dependencies = data.frame(
 +
Name = c(
 +
"stockBuildings",
 +
"efficiencyShares"
 +
),
 +
Ident = c(
 +
"Op_en7115/stockBuildings", # [[Building stock in Helsinki]]
 +
"Op_en5488/efficiencyShares" # [[Energy use of buildings]]
 +
)
 +
),
 +
formula = function(...) {
 +
 +
out <- oapply(stockBuildings, cols = c("Time", "Constructed"), FUN = sum)
 +
out <- out * 0.013125 * 5 * efficiencyShares # linear increase 42% from 2013 to 2050
 +
out@output <- out@output[as.numeric(as.character(out@output$Time)) >= 2015 , ]
  
'''Table 1. Effective floor area of buildings by building type.
+
return(out)
 +
}
 +
)
  
<t2b name="Effective floor area of buildings" index="Building,Year" locations="Baseline,2020,2025,2050" unit="m2" desc="Year of baseline,Type of data,Quality,Description">
+
objects.store(changeBuildings)
Residential|27884795|32472388|34890241|44069914|2014|||Building stock of Helsinki area, 2014
+
cat("Ovariable changeBuildings stored.\n")
Public|4537025|4764475|4945952|5855546|2014|||Building stock of Helsinki area, 2014
+
 
Industrial|3277271|3306063|3360467|3640854|2014|||Building stock of Helsinki area, 2014
+
</rcode>
Other|10861972|11406505|11840973|13806423|2014|||Building stock of Helsinki area, 2014
+
 
 +
'''Fraction of houses demolished per year.
 +
 
 +
<t2b name="Demolition rate" index = "Age" obs="Rate" unit="% /a">
 +
0|0
 +
50|1
 +
1000|1
 
</t2b>
 
</t2b>
  
;Notes:
+
<rcode name="demolitionRate" label="Initiate demolitionRate (for developers only)" embed=1>
* Estimates were based on {{#l:Siemens City Performance toolin seuraava kokous 2.2.pdf}} and some derived calculations on {{#l:BUILDING STOCK CALCULATION 2015.xlsx}}.
+
# This code is Op_en7115/demolitionRate on page [[Building stock in Helsinki]]
* How to get the numbers for the ''baseline floor area'' for residential, public, industrial and other: Residential floor area was named as residential together, public by summing the floor area of health care, education  and common  buildings, industrial buildings were as such and other buildings comprise of business, traffic, office and storage buildings.
+
library(OpasnetUtils)
* Ref. Helsinki master plan for 2050: there are 860 000 citizens living in Helsinki  (ref. www.yleiskaava.fi, visio2050);  Residental buildings => fast growth
+
 
* Prediction of citizen number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
+
demolitionRate <- Ovariable('demolitionRate',
* Helsinki’s climate policy: 30% reduction in emissions:  In 2010 the proportion of jobs in services and public sectors was 94%, and in industry 6%.  In 2020 the proportion of jobs in services and public sectors is estimated to be 96%, and in industry 4%. Public and other buildings => between fast growth option and basic option, Industry=> Basic option
+
dependencies = data.frame(Name = "dummy"),
** {{defend|#| It was a good idea to use the 30 % emissions reduction report for the scenarios!|[[User:Signatiu|Signatiu]]}}
+
formula = function(...) {
* Prediction of job number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
+
temp <- tidy(opbase.data('Op_en7115', subset = 'Demolition rate'))
* {{#l:Tables one and two.pdf}} The presentation of Tables 1 and 2
+
temp$Age <- round(as.numeric(as.character(temp$Age)))
* Estimates for floor area development are asked from Alpo Tani (KSV) and Olli-Pekka Pietiläinen (SYKE) as well (26.5.). No answers yet.
+
out <- as.data.frame(approx(
 +
temp$Age,  
 +
temp$Result,  
 +
n = (max(temp$Age) - min(temp$Age) + 1),
 +
method = "constant"
 +
))
 +
colnames(out) <- c("Age", "demolitionRateResult")
 +
out$demolitionRateResult <- out$demolitionRateResult / 100 * 10 # For ten-year intervals
 +
out <- Ovariable("demolitionRate", output = out, marginal = c(TRUE, FALSE))
 +
return(out)
 +
}
 +
)
 +
 
 +
objects.store(demolitionRate)
 +
cat("Object demolitionRate stored.\n")
  
''Technical notes'':
+
</rcode>
: Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Absolute increase/decrease rate will be based on the inhabitants projected in time.
 
: This is another list building types that was considered but rejected as too complex: Residential buildings, Government & public administration buildings, Commercial offices buildings, Data centers buildings, Education and K12 and universitiy buildings, Hospitals and healthcare buildings, Hotels and hospitality and leisure buildings, Exhibitions and fairs and halls buildings, Retail and stores and shops buildings, Warehouses & shopping mall buildings, Industrial buildings, Non residential buildings unspecified
 
Types of data used in CyPT:
 
* Average, City
 
* Example, city
 
* Average, city close by
 
* Example, city close by
 
* Average, national
 
* Example, country
 
Qualities of data used in CyPT
 
* Statistics
 
* Extrapolated
 
* Calculated from statistics
 
* Calculated from stat. inc. assumptions
 
  
 +
=== Heating type conversion ===
  
'''Table 2. Existing situation of important energy parametres in the building stock.
+
The fraction of heating types in the building stock reflects the situation at the moment of construction and not currently. The heating type conversion corrects this by changing a fraction of heating methods to a different one at different timepoints. Cumulative fraction, other timepoints will be interpolated.  
  
<t2b name="Existing situation of total stock" index="Property,Building" locations="Residential,Public,Industrial,Other" desc="Description" unit="%">
+
<t2b name='Yearly_heating_converted_factor' index='Heating_from,Heating_to,Time' unit='m2/m2'>
Wall insulation|17||||Default building data - Helsinki.xlsx and CyPT Data collection - To Jouni.pptx
+
Oil|Geothermal|2005|0
High efficient glazing|35|||| Energy performance class A in building automation and www.siemens.com
+
Oil|Geothermal|2015|0.5
Efficient lighting in baseline|1.4||||Default building data - Helsinki.xlsx
+
Oil|Geothermal|2025|1
Demand oriented lighting|26.9||||Default building data - Helsinki.xlsx
 
Building Efficiency Monitoring|||||
 
Building Remote Monitoring|||||
 
Building Performance Optimization|||||
 
Demand controlled ventilation|16.2 - 22.4||||Default building data - Helsinki.xlsx: Non-residential, cell C35
 
Heat and Cold Recovery in ventilation|17.8||||
 
Efficient Motors|||||
 
Building Automation BACS Class C|||||
 
Building Automation BACS Class B|||||
 
Building Automation BACS Class A|||||
 
Room Automation HVAC|30||||www.siemens.com
 
Room Automation HVAC + lighting|||||
 
Building Automation HVAC + lighting + blinds|60||||www.siemens.com
 
 
</t2b>
 
</t2b>
  
;Notes: Data from:
+
<rcode name="heatTypeConversion" label="Initiate heatTypeConversion(developers only)" embed=1>
* {{#l:CyPT Data collection - To Jouni.pptx}}
+
library(OpasnetUtils)
* {{#l:Default Building Data - Helsinki.xlsx}}
 
* [http://www.siemens.com/download?A6V10330398 Energy performance class A in building automation] www.siemens.com [http://www.buildingtechnologies.siemens.com]
 
The numbers found are not reliable but most of the high technology buildings such as insulated walls, windows.... are started to build from 10 to 15 years ago, so if we could find the building area in the year 2000, we could subtract that from the building area in Helsinki at the moment and get the building area which is built during these 10-15 years and they are high tech building areas with regard to 2 % renovation rate and rebuilding which is on going every year which should be added to the total amount.
 
  
''Technical notes:'' Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT.
+
heatTypeConversion <- Ovariable("heatTypeConversion",  
 +
dependencies = data.frame(
 +
Name = c(
 +
"buil", # stock at different timepoints
 +
"obstime"
 +
)
 +
),
 +
formula = function(...) {
 +
dat <- opbase.data("Op_en7115", subset = "Yearly_heating_converted_factor")
 +
colnames(dat)[colnames(dat) == "Time"] <- "Obsyear"
  
==== Energy demand ====
+
dat$Obs <- NULL
 +
 +
out <- data.frame()
 +
temp <- unique(dat[c("Heating_from", "Heating_to")])
 +
for (i in 1:nrow(temp)) {
 +
onetype <- merge(temp[i,], dat)
 +
tempout <- merge(obstime@output, onetype, all.x = TRUE)[c("Obsyear","Result")]
 +
tempout <- merge(tempout, temp[i,])
 +
 +
for (j in (1:nrow(tempout))[is.na(tempout$Result)]) {
 +
a <- onetype$Obsyear[which.min(abs(as.numeric(as.character(onetype$Obsyear)) - as.numeric(as.character(obstime$Obsyear[j]))))]
 +
tempout$Result[j] <- onetype$Result[a]
 +
}
 +
out <- rbind(out, tempout)
 +
}
 +
 +
out <- Ovariable(output = out, marginal = colnames(out) != "Result")
 +
 +
colnames(out@output)[colnames(out@output) == "Heating_from"] <- "Heating"
  
'''Table 3. Total energy demand by energy type and building type.
+
out <- buil * out
 +
 +
out1 <- out
 +
out1$Result <- - out1$Result
 +
out1$Heating_to <- NULL
 +
 +
out$Heating <- out$Heating_to
 +
out$Heating_to <- NULL
 +
 +
out@output <- rbind(out1@output, out@output)
 +
 +
#sum(out$Result)
 +
#nrow(out1@output)*2 - nrow(out@output)
 +
 +
return(out)
 +
}
 +
)
 +
objects.store(heatTypeConversion)
 +
cat("Ovariable heatTypeConversionstored.\n")
 +
</rcode>
  
<t2b name="Total energy demand by type" index="Energy type,Building" locations="Residential,Public,Industrial,Other" desc="Description" unit="kWh /m2 /a">
+
=== Renovations ===
Electricity|||||
+
 
Cooling|||||
+
Estimates from Laura Perez and Stephan Trüeb, unibas.ch N:\YMAL\Projects\Urgenche\WP9 Basel\Energy_scenarios_Basel_update.docx
Heating|||||
+
 
 +
<t2b name='Fraction of houses renovated per year' index="Age" obs="Result" desc="Description" unit= "%">
 +
0|0|Estimates from Laura Perez and Stephan Trüeb
 +
20|0|Assumption Result applies to buildings older than the value in the Age column.
 +
25|1|
 +
30|1|
 +
50|1|
 +
100|1|
 +
1000|1|
 
</t2b>
 
</t2b>
  
;Notes: Heating includes warm water.  
+
<rcode name="renovationRate" label="Initiate renovationRate (developers only)" embed=1>
:{{comment|# |See [[Helsinki energy decision 2015]]. More of relevant data may be collected there.|--[[User:Jouni|Jouni]] ([[User talk:Jouni|talk]]) 14:16, 19 May 2015 (UTC)}}
+
library(OpasnetUtils)
:{{comment|# |These numbers could be estimated from the [[Building model]] when teh Facta data is applied. We are planning to do that in early June, 2015.|--[[User:Jouni|Jouni]] ([[User talk:Jouni|talk]]) 08:22, 21 May 2015 (UTC)}}
+
 
 +
renovationRate <- Ovariable('renovationRate',
 +
dependencies = data.frame(Name = "dummy"),
 +
formula = function(...) {
 +
temp <- tidy(opbase.data('Op_en7115', subset = 'Fraction of houses renovated per year'))
 +
temp$Age <- round(as.numeric(as.character(temp$Age)))
 +
out <- as.data.frame(approx(
 +
temp$Age,
 +
temp$Result,
 +
n = (max(temp$Age) - min(temp$Age) + 1),
 +
method = "constant"
 +
))
 +
colnames(out) <- c("Age", "renovationRateResult")
 +
out$renovationRateResult <- out$renovationRateResult / 100
 +
out <- Ovariable("renovationRate", output = out, marginal = c(TRUE, FALSE))
 +
return(out)
 +
}
 +
)
  
''Technical notes:'' Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries PPT.
+
objects.store(renovationRate)
 +
cat("Object renovationRate stored.\n")
  
'''Table 4. Shares of different energy sinks by building type.
+
</rcode>
  
<t2b name="Share of energy demand by use type" index="Energy type,Use,Building" locations="Residential,Other,Public,Industry" unit="kWh /m2 /a" desc="Description,Auxiliaries">
+
<t2b name='Popularity of renovation types' index='Renovation' obs='Fraction' desc='Description' unit='%'>
Cooling|Infiltration|0.0|0.0|0.0|0.0||PPT
+
None|0|
Cooling|Ventilation|0.0|0.0|0.0|9.0||PPT
+
Windows|65|
Cooling|Losses through walls through transmission|0.0|0.0|0.0|0.0||PPT
+
Technical systems|30|
Cooling|Heat input by solar radiation through windows|0.0|0.0|0.0|0.0||PPT
+
Sheath reform|5|
Cooling|Losses through windows through transmission|0.0|0.0|0.0|0.0||PPT
+
General|0|
Cooling|Other effects (e.g. people, electrical Appliances)|0.0|0.0|0.0|0.0||PPT
 
Heating|Infiltration|0.0|0.0|0.0|0.0||PPT
 
Heating|Ventilation|29.19|27.56|27.22|27.22||PPT
 
Heating|Walls|34.75|32.81|32.40|32.40||PPT
 
Heating|Windows|15.49|14.63|14.44|14.44||PPT
 
Heating|Floors|8.74|8.25|8.15|8.15||PPT
 
Heating|Roofs|9.33|8.81|8.70|8.70||PPT
 
Heating|Other|0.0|0.0|0.0|0.0||PPT
 
Heating|Warm water|1.89|0.0|1.76|1.76||Copenhagen Excel
 
Electricity|Lighting|2.82|20.05|49.68|8.67||Copenhagen Excel
 
Electricity|Appliances|24.84|18.74|14.19|13.00||Copenhagen Excel
 
Electricity|Ventilation|0|12.03|21.29|18.24||Copenhagen Excel
 
Electricity|Other|0.56|23.69|56.77|51.76||Copenhagen Excel
 
 
</t2b>
 
</t2b>
  
;Notes:
+
<rcode name="renovationShares" label="Initiate renovationShares (developers only)" embed=1>
* Data from {{#l:Climate policies Helsinki additional data.zip}}
+
library(OpasnetUtils)
* We went through the data mentioned above and also the files given in {{#l:Climate policies Helsinki data.zip}} but could not find the data for cooling, heating:infiltration, heating:other, heating:warm water:other and electricity:ventilation:residential.
+
 
* Total estimated amount of energy needed for cooling 23504480 kWh/a (whole Helsinki). Based on [http://www.energiatehokashelsinki.fi/energiankulutus/Helsinki] 14332 GWh/a for housing (total energy demand minus traffic 18 % [http://www.stadinilmasto.fi/files/2013/04/PEK-raportti.pdf] and [http://www.korjaustieto.fi/pientalot/pientalojen-energiatehokkuus/energiatehokkuus-pientaloissa/pientalon-energiankulutus-ja-paastot.html] 2 % of total energy demand of housing used for cooling. Total floor area of Helsinki needed (table 1).
+
renovationShares <- Ovariable("renovationShares",
 +
dependencies = data.frame(Name = "dummy"),
 +
formula = function(...) {
 +
out <- Ovariable("raw", ddata = 'Op_en7115', subset = 'Popularity of renovation types')
 +
out <- findrest((out), cols = "Renovation", total = 100) / 100
 +
 
 +
renovationyear <- Ovariable("renovationyear", data = data.frame(
 +
Obsyear = factor(c(2015, 2025, 2035, 2045, 2055, 2065)),
 +
Result = 1
 +
))
  
''Technical notes:'' Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 1. Auxiliaries: see table.
+
out <- out * renovationyear # renovation shares repeated for every potential renovation year.
  
 +
out@output$Renovation <- factor(out@output$Renovation, levels = c(
 +
"None",
 +
"General",
 +
"Windows",
 +
"Technical systems",
 +
"Sheath reform"
 +
), ordered = TRUE)
  
'''Table 5. Changes in energy efficiency of different energy sinks.
+
return(out)
 +
}
 +
)
  
<t2b name="Efficiency increase decreasing energy demand" index="Energy type,Use,Building" locations="Residential,Public,Industrial,Other" desc="Description" unit="% /a">
+
objects.store(
Electricity|Lighting /Lamp stock|0.6|0.6|0.6|0.6|
+
renovationShares # Fraction of renovation type when renovation is done.
Electricity|Appliances|0.6|0.6|0.6|0.6|
+
)
Electricity|Ventilation|0.6|0.6|0.6|0.6|
 
Electricity|Other|0.6|0.6|0.6|0.6|
 
Cooling|Infiltration|2|0.6|0.6|0.6|
 
Cooling|Ventilation|2|0.6|0.6|0.6|
 
Cooling|Other (e.g. electric appliances, people)|2|0.6|0.6|0.6|
 
Heating|Infiltration|0.6|0.6|0.6|0.6|
 
Heating|Ventilation|0.6|0.6|0.6|0.6|
 
Heating|Floors|0.6|0.6|0.6|0.6|
 
Heating|Roofs|0.6|0.6|0.6|0.6|
 
Heating|Other reasons|0.6|0.6|0.6|0.6|
 
Heating|Warm water|1.1|0.6|0.6|0.6|
 
</t2b>
 
  
;Notes:
+
cat("Objects renovationShares stored.\n")
* Estimated 3 % of houses renovated/year and 20 % increase in energy efficiency when renovated. [http://www.hel.fi/static/rakvv/ohjeet/energiatehokkuus_korjaamisessa.pdf] Data apart from 0.6% values from {{#l:Climate policies Helsinki additional data.zip}}
 
* The presentation about tables 4 and 5 {{#l:PresentationHW9.pptx}}
 
  
''Technical notes:''  Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel.
+
</rcode>
 +
<noinclude>
 +
=== Locations of city areas ===
  
 +
;Locations of city areas (hidden for readability).
  
'''Table 6. Important energy parameters.
+
{{hidden|
 +
The positions listed here are used for exposure modelling. Area code matches with stock detail data on [[Building stock in Helsinki]]. The coordinates should be visually checked from http://www.karttapaikka.fi referencing picture X.
  
<t2b name="Energy parameters" index="Parameter,Unit,Building" locations="Residential,Public,Industrial,Other" unit="-" desc="Description,Auxiliary">
+
<t2b name="Locations of city areas" index="City_area,Area code,Location" locations="N,E" unit="epsg:ETRS-TM35FIN">
Ratio of wall area / effective area|-|0.00|0.00|0.00|0.00||PPT
+
001|KRU|6672352|386953
Ratio of window/effective area|-|0.00|0.00|0.00|0.00||PPT
+
002|KLU|6672912|385513
U-value of windows|W /m2 /K|1.0|1.4|1.4|1.4||PPT
+
003|KAA|6671692|386153
Solar heat gain coefficient "G-Value" of windows|%|0.40|0.0|0.0|0.0||PPT
+
004|KAM|6671692|385233
Efficiency increase of G-value of windows|% /a|0.0|0.0|0.0|0.0||Excel
+
005|PUN|6671352|385113
Efficiency increase of U-value of windows|% /a|0.0|0.0|0.0|0.0||Excel
+
006|E|6670792|385573
U-value of building walls|W /m2 /K|0.16|0.25|0.25|0.28||PPT
+
007|UL|6670372|385973
 +
008|KAT|6671752|387933
 +
009|KAI|6670632|387573
 +
010|SÖR|6674072|387453
 +
011|KAL|6673712|385933
 +
012|ALP|6673712|385933
 +
013|ETU|6672552|383733
 +
014|TAK|6673472|384753
 +
015|ARI|6673872|382813
 +
016|RUS|6676072|383793
 +
017|PAS|6676092|385093
 +
018|LAA|6675052|384433
 +
019|MUSKOR|6672592|388413
 +
020|LÄN|6670552|384033
 +
021|HER|6675432|387573
 +
022|VAL|6674912|386573
 +
023|TOU|6676272|387793
 +
024|KUM|6676192|386593
 +
025|KÄP|6676932|386153
 +
026|KOS|6677812|387393
 +
027|VAN|6676972|387933
 +
028|OUL|6678952|386533
 +
029|HAA|6678032|383353
 +
030|MUN|6674752|381733
 +
031|LAU|6670952|381593
 +
032|KON|6679852|380593
 +
033|KAA|6680752|382413
 +
034|PAK|6680392|385993
 +
035|TUO|6682492|385653
 +
036|VII|6676912|389553
 +
037|PUK|6680352|388573
 +
038|MAL|6680252|390153
 +
039|TAP|6682632|389273
 +
040|SUUT|6684152|389693
 +
041|SUUR|6682512|393113
 +
042|KUL|6674292|389193
 +
043|HER|6675272|391093
 +
044|TAM|6674252|392653
 +
045|VAR|6677372|394013
 +
046|PIT|6678172|381453
 +
047|MEL|6679192|394193
 +
048|VAR|6672872|393793
 +
049|LAA|6672072|391593
 +
050|VIL|6670412|395553
 +
051|SAN|6668612|392993
 +
052|SUO|6668912|388813
 +
053|ULK|6666992|395973
 +
054|VUO|6675252|397553
 +
055|ÖST|6681312|399633
 +
056|SAL|6679252|3985130
 +
057|TAL|6679452|400333
 +
058|KAR|6680652|401453
 +
059|ULT|6683472|400453
 +
401||6684572|390899
 +
402||6680780|382563
 +
403||6677628|383571
 +
404||6682460|385139
 +
405||6675756|391603
 +
406||6679980|391731
 +
407||6679724|380771
 +
408||6676828|387779
 +
409||6673900|389379
 +
410||6675708|386355
 +
411||6678556|387027
 +
412||6671724|392691
 +
413||6674156|391539
 +
414||6668124|381699
 +
415||6673356|380707
 +
417||6677388|399763
 +
418||6680476|390883
 +
419||6678956|395043
 +
420||6676332|381987
 +
421||6683244|385635
 +
422||6678972|386803
 +
423||6680252|385939
 +
424||6679740|388819
 +
425||6669196|391683
 +
426||6683676|388515
 +
427||6684108|389843
 +
428||6678156|381315
 +
429||6682524|391027
 +
430||6672204|391459
 +
431||6681740|386131
 +
432||6672924|385635
 +
433||6677196|394211
 +
434||6678188|390147
 +
435||6676380|397027
 +
436||6676380|384755
 +
437||6674156|383123
 +
438||6682316|398147
 +
439||6679612|400499
 +
440||6684124|402355
 +
441||6679724|399027
 +
442||6682076|400499
 +
878||6678380|390771
 +
895||6678380|390771
 
</t2b>
 
</t2b>
 +
}}
  
;Notes:
+
=== Data not used ===
* Data used: [[Unit heat consumption of buildings in Finland]].
 
* Data {{#l:Climate policies Helsinki additional data.zip}} only contained 0.00 for all the parameters.
 
* EU legislation value for U-value of windows in the document below was 1.0, so we used it for building buildings and the past years' values for the non-residential buildings. We assumed this will be the new residential buildings to be within the legislative value. <ref>Economidou, M., Atanasiu, B., Despret, C., Maio, J., Nolte, I., & Rapf, O. (2011). Europe’s buildings under the microscope. A Country-by-country review of the energy performance of buildings, 131.</ref> <ref>Kragh, J., Laustsen, J. B., & Svendsen, S. (2008). Proposal for Energy Rating System of windows in EU. DTU Civil Engineering-Report R-201.</ref> <ref>http://www.ziegel.at/gbc-ziegelhandbuch/eng/ressourcen/energie/graue.htm</ref>
 
* HW9 table 6 presentation: {{#l:Helsinki Building Stock.pptx}}
 
 
 
''Technical notes:'' Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries: see table.
 
  
Values derived from [[Unit heat consumption of buildings in Finland]] (these could be used to update Table 6):
+
This contains data that was not used in the model's calculations. This includes renovation rates, the rates of heat flowing out of buildings and total floor areas of multiple types of buildings in Helsinki. The floor area data is also found in the background data of this page, which was used in the model.
  
 
{| {{prettytable}}
 
{| {{prettytable}}
|+ '''Important energy parameters
+
|+'''Effective floor area of buildings by building type.
!Parameter || Value || Table ||Description
 
|----
 
|| Efficiency increase of U values walls 1/a|| 0.019642857|| u.factor||(0.28-0.17)/0.28/(2010-1990)
 
|----
 
|| Efficiency increase of U values windows 1/a|| 0.014285714|| u.factor||(1.4-1)/1.4/(2010-1990)
 
 
|----
 
|----
|| U value wall W/m2/K|| 0.17-0.28|| u.factor||values for buildings built 1990-2010
+
|| Building|| Baseline|| 2020|| 2025|| 2050|| Year of baseline|| Description
 
|----
 
|----
|| U value window W/m2/K|| 1.0-1.4|| u.factor||values for buildings built 1990-2010
+
|| Residential|| 27884795|| 32472388|| 34890241|| 44069914|| 2014|| Building stock of Helsinki area, 2014
 
|----
 
|----
|| G value %|| 70|| sun.heat.absorption.parameters||
+
|| Public|| 4537025|| 4764475|| 4945952|| 5855546|| 2014|| Building stock of Helsinki area, 2014
 
|----
 
|----
|| Ratio of wall/effective area|| 0.647727273|| surface.area|| year 2010: 114/176
+
|| Industrial|| 3277271|| 3306063|| 3360467|| 3640854|| 2014|| Building stock of Helsinki area, 2014
 
|----
 
|----
|| Ratio of window/effective area|| 0.1|| surface.area|| year 2010: 17.6/176
+
|| Other|| 10861972|| 11406505|| 11840973|| 13806423|| 2014|| Building stock of Helsinki area, 2014
 
|----
 
|----
 
|}
 
|}
  
==== Lighting ====
+
;Notes:
 +
* Estimates were based on {{#l:Siemens City Performance toolin seuraava kokous 2.2.pdf}} and some derived calculations on {{#l:BUILDING STOCK CALCULATION 2015.xlsx}}.
 +
* How to get the numbers for the ''baseline floor area'' for residential, public, industrial and other: Residential floor area was named as residential together, public by summing the floor area of health care, education  and common  buildings, industrial buildings were as such and other buildings comprise of business, traffic, office and storage buildings.
 +
* Ref. Helsinki master plan for 2050: there are 860 000 citizens living in Helsinki  (ref. www.yleiskaava.fi, visio2050);  Residental buildings => fast growth
 +
* Prediction of citizen number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
 +
* Helsinki’s climate policy: 30% reduction in emissions:  In 2010 the proportion of jobs in services and public sectors was 94%, and in industry 6%.  In 2020 the proportion of jobs in services and public sectors is estimated to be 96%, and in industry 4%. Public and other buildings => between fast growth option and basic option,  Industry=> Basic option
 +
* Prediction of job number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
 +
* {{#l:Tables one and two.pdf}} The presentation of Tables 1 and 2
  
'''Tables 7-8. Run times and shares of lamps by lamp type and building type.
 
  
<t2b name="Average run time of lamps per year" index="Lamp,Building" locations="Residential,Public,Industrial,Other" desc="Description" unit="h /a">
+
''Technical notes'':
Incandescent lamps|||||
+
: Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Absolute increase/decrease rate will be based on the inhabitants projected in time.
Compact fluorescent lamps|||||
+
: This is another list building types that was considered but rejected as too complex: Residential buildings, Government & public administration buildings, Commercial offices buildings, Data centers buildings, Education and K12 and universitiy buildings, Hospitals and healthcare buildings, Hotels and hospitality and leisure buildings, Exhibitions and fairs and halls buildings, Retail and stores and shops buildings, Warehouses & shopping mall buildings, Industrial buildings, Non residential buildings unspecified.
Fluorescent lamps|||||
+
* There was a problem with missing data. There is more than 400000 m^2 floor area that is missing; this is estimated from total area that is available for these buildings. For other buildings, there is more than 400000 m^2 total area missing from buildings where floor area is given. See statistical analysis [http://en.opasnet.org/en-opwiki/index.php?title=Special:RTools&id=026ekUv81jP0A6rI]. This was corrected by inputation so that is floor area was missing, 0.8*total_area was used instead [http://en.opasnet.org/en-opwiki/index.php?title=Special:RTools&id=oE7UXNQt3Izdo4tE].
Low voltage halogen lamps|||||
 
Medium voltage halogen lamps|||||
 
</t2b>
 
  
<t2b name="Shares of lamp types" index="Lamp,Building" locations="Residential,Public,Industrial,Other" desc="Description" unit="%">
+
{| {{prettytable}}
Incandescent lamps|||||
+
|+ Renovations per year made in residental buildings owned by Helsinki city, by construction year of the buildings.<ref name="uarvo">[http://www.tut.fi/ee/en/Materiaali/HAESS_loppuraportti_TTY_14062010.pdf HAESS Final report], Tampere University of Technology, 2010</ref>
Compact fluorescent lamps|||||
+
|---
Fluorescent lamps|||||
+
! Construction year !! Balcony glasses !! Windows !! Julkisivujen peruskorjaus !! Vesikattojen peruskojaus !! Lämmönvaihtimen uusiminen !! Patteriverkoston säätö !! Kylpyhuonekalusteiden vaihto !! Patteriventtiilien vaihto !! New balcony doors !! LTO-laitteen asennus !! Water consumption measurements
Low voltage halogen lamps|||||
+
|---
Medium voltage halogen lamps|||||
+
| -20 || 0,0 % || 1,1 % || 1,1 % || 1,1 % || 1,1 % || 1,1 % || 1,1 % || 1,1 % || 1,1 % || 1,1 % || 1,1 %
</t2b>
+
|---
 +
| 21-25 ||0,0 % || 10,3 % || 1,2 % || 11,1 % || 10,3 % || 10,3 % || 1,2 % || 10,3 % || 1,2 % || 10,3 % || 10,3 %
 +
|---
 +
| 26-30 || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 9,5 % || 0,0 %
 +
|---
 +
| 31-35 || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 0,0 %
 +
|---
 +
| 36-40 || 0,0 % || 0,0 % || 0,0 % || 0,0 % || 4,2 % || 4,2 % || 0,0 % || 0,0 % || 0,0 % || 4,2 % || 0,0 %
 +
|---
 +
| 41-45 || 0,0 % || 16,7 % || 0,0 % || 16,7 % || 16,7 % || 16,7 % || 0,0 % || 16,7 % || 0,0 % || 16,7 % || 16,7 %
 +
|---
 +
| 46-50 || 0,0 % || 5,2 % || 0,0 % || 7,4 % || 7,4 % || 7,4 % || 0,0 % || 7,4 % || 0,0 % || 5,2 % || 5,2 %
 +
|---
 +
| 51-55 || 0,0 % || 11,3 % || 0,0 % || 8,8 % || 8,8 % || 8,8 % || 0,0 % || 8,8 % || 0,0 % || 8,8 % || 16,2 %
 +
|---
 +
| 56-60 || 0,0 % || 5,4 % || 0,0 % || 4,9 % || 6,2 % || 7,1 % || 0,0 % || 6,2 % || 4,5 % || 4,5 % || 5,4 %
 +
|---
 +
| 61-65 || 0,0 % || 1,5 % || 1,3 % || 0,8 % || 2,9 % || 2,4 % || 1,0 % || 2,4 % || 0,9 % || 0,9 % || 2,9 %
 +
|---
 +
| 66-70 || 0,6 % || 2,9 % || 1,2 % || 2,8 % || 1,4 % || 2,3 % || 1,1 % || 1,1 % || 0,1 % || 1,1 % || 1,1 %
 +
|---
 +
| 71-75 || 3,2 % || 3,1 % || 3,4 % || 2,9 % || 3,1 % || 2,6 % || 0,2 % || 1,1 % || 0,2 % || 0,2 % || 0,2 %
 +
|---
 +
| 76-80 || 0,1 % || 2,7 % || 0,1 % || 0,7 % || 2,0 % || 1,7 % || 1,1 % || 1,2 % || 0,2 % || 0,4 % || 0,2 %
 +
|---
 +
| 81-85 || 1,0 % || 2,8 % || 0,7 % || 2,3 % || 3,3 % || 4,8 % || 3,5 % || 0,0 % || 0,0 % || 0,0 % || 0,8 %
 +
|---
 +
| 86-90 || 0,0 % || 1,3 % || 0,0 % || 2,1 % || 6,1 % || 1,6 % || 0,7 % || 1,8 % || 0,3 % || 0,3 % || 1,0 %
 +
|---
 +
| 91-95 || 0,6 % || 0,3 % || 0,0 % || 3,9 % || 8,6 % || 1,9 % || 5,1 % || 0,8 % || 0,2 % || 0,0 % || 1,3 %
 +
|---
 +
| 96-00 || 0,1 % || 0,0 % || 0,0 % || 0,6 % || 1,2 % || 1,0 % || 1,5 % || 1,0 % || 0,0 % || 0,0 % || 4,2 %
 +
|---
 +
| 01-05 || 2,9 % || 0,0 % || 0,0 % || 0,0 % || 1,2 % || 1,0 % || 0,0 % || 1,0 % || 0,0 % || 0,0 % || 0,7 %
 +
|---
 +
| 06-10 || 1,7 % || 0,0 % || 0,0 % || 0,0 % || 0,5 % || 0,5 % || 0,0 % || 0,5 % || 0,0 % || 0,0 % || 0,0 %
 +
|}
  
;Notes: Sheets 5_Input Residential, 6.0_Input Non Residential, 6.2_Input Public Admin. Priority 3. Auxiliaries Excel.
+
{{defend|# |In the document there are similar tables for total renovations from 2010 onwards to years 2016, 2020 and 2050.|--[[User:Heta|Heta]] ([[User talk:Heta|talk]]) 09:28, 16 June 2015 (UTC)}}
  
==== Other ====
+
{| {{prettytable}}
 
+
|+'''Toimenpiteiden vaikutukset yksittäisessä kohteessa ja toimenpiteisiin liittyviä huomautuksia.<ref name="uarvo"/>
Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Nice to have specific factor otherwise we adapt standard data or other studies.
+
|---
 +
! Action !! The feature in question !! Difference to before !! Unit !! Notes
 +
|---
 +
| Glass for balconies || U-value for windows || -0,3 || W/m<sup>2</sup>,K || Säästö 1-4% rakennustasolla
 +
|--
 +
| Changing the windows || U-value for windows || -1 || W/m<sup>2</sup>,K || Vanhoista osa kaksilasisia ja osa kolmilasisia. Uudes 1,0  W/m<sup>2</sup>,K tai alle
 +
|---
 +
| Julkisivun peruskorjaus || U-value of walls || -0,2 ||  W/m<sup>2</sup>,K || U-arvo puolitetaan eli n. 100 mm lisäeristys
 +
|---
 +
| Vesikattojen peruskorjaus || Yläpohjan U-arvo || -0,15 ||  W/m<sup>2</sup>,K || Oletetaan 50% lisäeristys U-arvo puoleen eli n. 100 mm lisäerstys
 +
|---
 +
| Balcony door change || U-value of doors || -0,5 ||  W/m<sup>2</sup>,K || Tiivistyminen tuo lisäsäästöä
 +
|}
  
 
{| {{prettytable}}
 
{| {{prettytable}}
|+''Possibly important information
+
|+'''Thermal transmittances of building components and air flow rates. Averaged values calculates from the detailed model are presented here.<ref>MK Mattinen, J Heljo, J Vihola, A Kurvinen, S Lehtoranta, A Nissinen: Modeling and visualisation of residential sector energy consumption and greenhouse gas emissions</ref>
!Data!!Result
+
|---
|----
+
|colspan="2" rowspan="2"| Construction decade ||colspan="5"| Thermal transmittance factors for building components (W/m2K) ||colspan="3"| Ventilation and leakage air rates (1/h)
|Number of households||
+
|---
|----
+
| Floor || Roof || Walls || Windows || Outdoors || Supply air through the heat recovery unit || Supply air bypassing the heat recovery unit || Leakage air
|Number of persons per household||
+
|---
 +
|rowspan="3"| Before 1980 || Single family house || 0.52 || 0.32 || 0.54 || 2.14 || 1.18 || 0.30 || 0.05 || 0.20
 +
|---
 +
| Row house || 0.52 || 0.36 || 0.56 || 2.15 || 1.00 || 0.3 || 0.05 || 0.20
 +
|---
 +
| Apartment building || 0.59 || 0.37 || 0.61 || 2.18 || 1.40 || 0.37 || 0.00 || 0.10
 +
|---
 +
|rowspan="3"| 1980's || Single family house || 0.30 || 0.21 || 0.28 || 1.70 || 1.00 || 0.30 || 0.05 || 0.15
 +
|---
 +
| Row house || 0.32 || 0.22 || 0.30 || 1.70 || 1.00 || 0.30 || 0.05 || 0.15
 +
|---
 +
| Apartment building || 0.34 || 0.23 || 0.29 || 1.80 || 1.40 || 0.35 || 0.00 || 0.10
 +
|---
 +
|rowspan="3"| 1990's || Single family house || 0.25 || 0.20 || 0.25 || 1.70 || 1.00 || 0.30 || 0.05 || 0.15
 +
|---
 +
| Row house || 0.32 || 0.22 || 0.28 || 1.70 || 1.00 || 0.30 || 0.05 || 0.15
 +
|---
 +
| Apartment building || 0.332 || 0.22 || 0.28 || 1.75 || 1.40 || 0.38 || 0.00 || 0.10
 +
|---
 +
|rowspan="3"| 2000's || Single family house || 0.24 || 0.17 || 0.24 || 1.40 || 1.00 || 0.30 || 0.05 || 0.13
 +
|---
 +
| Row house || 0.28 || 0.18 || 0.26 || 1.50 || 1.00 || 0.45 || 0.05 || 0.15
 +
|---
 +
| Apartment building || 0.28 || 0.18 || 0.26 || 1.50 || 1.40 || 0.55 || 0.00 || 0.10
 +
|---
 +
|rowspan="3"| 2010's || Single family house || 0.16 || 0.09 || 0.17 || 1.00 || 1.00 || 0.30 || 0.05 || 0.10
 +
|---
 +
| Row house || 0.16 || 0.09 || 0.17 || 1.00 || 1.00 || 0.50 || 0.05 || 0.15
 +
|---
 +
| Apartment building || 0.16 || 0.09 || 0.17 || 1.00 || 1.00 || 0.60 || 0.00 || 0.10
 
|}
 
|}
  
=== Facta database building categories and heating types ===
+
== See also ==
'''These tables are based on FACTA database classifications and their interpretation for assessments.
 
  
<t2b name="Building types" index="Building types in Facta" obs="Building" unit="-">
+
{{Helsinki energy decision 2015}}
Ammatilliset oppilaitokset|Public
 
Asuntolat, vanhusten palvelutalot, asuntolahotellit|Other
 
Elokuvateatterit|Public
 
Hotellit, motellit, matkustajakodit, kylpylähotellit|Public
 
Kahden asunnon talot|Residential
 
Kasvihuoneet|Industrial
 
Kauppavarastot|Industrial
 
Kirjastot|Public
 
Kirkot, kappelit, luostarit, rukoushuoneet|Public
 
Korkeakoulurakennukset|Public
 
Kulkuneuvojen suoja- ja huoltorakennukset|Industrial
 
Lasten päiväkodit|Public
 
Lastenkodit, koulukodit|Residential
 
Liike- ja tavaratalot, kauppakeskukset|Other
 
Monitoimi- ja muut urheiluhallit|Other
 
Museot, taidegalleriat|Public
 
Muut erilliset pientalot|Residential
 
Muut kerrostalot|Residential
 
Muut liikenteen rakennukset|Industrial
 
Muut palo- ja pelastustoimen rakennukset|Other
 
Muut sairaalat|Other
 
Muut teollisuuden tuotantorakennukset|Industrial
 
Muut terveydenhoitorakennukset|Other
 
Muut urheilu- ja kuntoilurakennukset|Other
 
Muut uskonnollisten yhteisöjen rakennukset|Public
 
Muut varastorakennukset|Other
 
Myymälärakennukset|Other
 
Peruskoulut, lukiot ja muut|Public
 
Pysäköintitalot|Other
 
Rautatie- ja linja-autoasemat, lento- ja satamaterminaalit|Public
 
Ravintolat, ruokalat ja baarit|Public
 
Rivitalot|Residential
 
Saunarakennukset|Other
 
Seurakuntatalot|Public
 
Talousrakennukset|Other
 
Teollisuus- ja pienteollisuustalot|Industrial
 
Teollisuushallit|Industrial
 
Toimistorakennukset|Other
 
Tutkimuslaitosrakennukset|Other
 
Vapaa-ajan asunnot|Residential
 
Voimalaitosrakennukset|Industrial
 
Väestönsuojat|Other
 
Yhden asunnon talot|Residential
 
Muualla luokittelemattomat opetusrakennukset|Other
 
Muut kokoontumisrakennukset|Public
 
Muut rakennukset|Other
 
Muut sosiaalitoimen rakennukset|Public
 
Myymälähallit|Other
 
Teollisuusvarastot|Industrial
 
Yhdyskuntatekniikan rakennukset|Other
 
Järjestöjen, liittojen, työnantajien yms. opetusrakennukset|Other
 
Muut huoltolaitosrakennukset|Industrial
 
Tietoliikenteen rakennukset|Industrial
 
Seurain-, nuoriso- yms. talot|Public
 
Terveyskeskukset|Public
 
Vanhainkodit|Residential
 
Luhtitalot|Residential
 
Navetat, sikalat, kanalat yms.|Industrial
 
Muut majoitusliikerakennukset|Other
 
Muut majoitusrakennukset|Other
 
Muut maa-, metsä- ja kalatalouden rakennukset|Other
 
Kehitysvammaisten hoitolaitokset|Residential
 
Loma- lepo- ja virkistyskodit|Other
 
Eläinsuojat, ravihevostallit, maneesit|Other
 
|Other
 
Paloasemat|Other
 
Vuokrattavat lomamökit ja osakkeet (liiketoiminnallisesti)|Other
 
Teatterit, konsertti- ja kongressitalot, oopperat|Public
 
Jäähallit|Public
 
Keskussairaalat|Other
 
Näyttelyhallit|Other
 
Terveydenhoidon erityislaitokset (mm. kuntoutuslaitokset)|Other
 
Viljankuivaamot ja viljan säilytysrakennukset, siilot|Industrial
 
Uimahallit|Public
 
Vankilat|Other
 
Ketjutalot|Residential
 
Tennis-, squash- ja sulkapallohallit|Other
 
</t2b>
 
 
 
<t2b name="Heating types" index="Heating types in Facta" obs="Heating" unit="-">
 
|Other
 
Kauko- tai aluelämpö|District heating
 
Kevyt polttoöljy|Light oil
 
Kivihiili, koksi tms.|Coal
 
Maalämpö tms.|Geothermal
 
Puu|Wood
 
Raskas polttoöljy|Fuel oil
 
Sähkö|Electricity
 
Kaasu|Gas
 
Muu|Other
 
</t2b>
 
 
 
=== Calculations ===
 
 
 
== See also ==
 
  
 +
* [[Building stock in Helsinki metropolitan area]]
 
* [http://en.opasnet.org/en-opwiki/index.php?title=Building_stock_in_Helsinki&oldid=35248#Calculations Descriptions about the summary calculations on sheet Parameter Balance] (not needed any more).
 
* [http://en.opasnet.org/en-opwiki/index.php?title=Building_stock_in_Helsinki&oldid=35248#Calculations Descriptions about the summary calculations on sheet Parameter Balance] (not needed any more).
 
* [http://ptp.hel.fi/paikkatietohakemisto/?id=125 Rakennustietoruudukko pääkaupunkiseudulta] [https://www.hsy.fi/fi/asiantuntijalle/avoindata/Sivut/AvoinData.aspx?dataID=14]
 
* [http://ptp.hel.fi/paikkatietohakemisto/?id=125 Rakennustietoruudukko pääkaupunkiseudulta] [https://www.hsy.fi/fi/asiantuntijalle/avoindata/Sivut/AvoinData.aspx?dataID=14]
 +
* [[Unit heat consumption of buildings in Finland]]
 +
* [http://era17.fi/wp-content/uploads/2010/10/sitran_selvityksia_39.pdf Sitra, page 25]
 +
* [http://www.teeparannus.fi/attachements/2010-12-21T11-54-1114846.pdf Tee parannus pages 8-9, also 40-45]
 +
* [http://www.vtt.fi/inf/pdf/tiedotteet/2007/T2377.pdf VTT tiedotteet page 20-21, also 30, 80]
 +
* [[Heating consumption of buildings]]
 +
* [http://www.tut.fi/ee/Tutkimus/lammike.html Lämmitystapavalintojen kehitys]
  
 
== References ==
 
== References ==
Line 345: Line 731:
 
== Related files ==
 
== Related files ==
 
<!-- __OBI_TS:1431310608 -->
 
<!-- __OBI_TS:1431310608 -->
 +
</noinclude>

Latest revision as of 05:23, 8 November 2015



During Decision analysis and risk management 2015 course, this page was used to collect student contributions. To see them, look at an archived version. The page has since been updated for its main use. Data in the archived tables was moved: Table 2. Energy parametres of buildings, Table 4. Energy sinks, Table 5. Changes in energy efficiency, Table 6. Important energy parametres. Tables 3, 7, and 8 did not contain data and were removed.


Question

What is the building stock in Helsinki and its projected future?

Answer

+ Show code

Rationale

This part contains the data needed for calculations about the building stock in Helsinki. It shows the different building and heating types in Helsinki, and how much and what kind of renovations are done for the existing building stock in a year, including how much and how old building stock is demolished. This data is used in further calculations in the model.

There is also some other important data that wasn't used in the model's calculations. These include more accurate renovation statistics for residential buildings, U-value changes for renovations and thermal transmittance of different parts of residential buildings. This data is found under Data not used.

Building stock

These tables are based on FACTA database classifications and their interpretation for assessments. This data is used for modelling. The data is large and can be seen from the Opasnet Base. Technical parts on this page are hidden for readability. Building types should match Energy use of buildings#Baseline energy consumption.



+ Show code

Construction and demolition

It is assumed that construction occurs at a constant rate so that there is an increase of 42% in 2050 compared to 2013. Energy efficiency comes from Energy use of buildings.

+ Show code

Fraction of houses demolished per year.

Demolition rate(% /a)
ObsAgeRate
100
2501
310001

+ Show code

Heating type conversion

The fraction of heating types in the building stock reflects the situation at the moment of construction and not currently. The heating type conversion corrects this by changing a fraction of heating methods to a different one at different timepoints. Cumulative fraction, other timepoints will be interpolated.

Yearly_heating_converted_factor(m2/m2)
ObsHeating_fromHeating_toTimeResult
1OilGeothermal20050
2OilGeothermal20150.5
3OilGeothermal20251

+ Show code

Renovations

Estimates from Laura Perez and Stephan Trüeb, unibas.ch N:\YMAL\Projects\Urgenche\WP9 Basel\Energy_scenarios_Basel_update.docx

Fraction of houses renovated per year(%)
ObsAgeResultDescription
100Estimates from Laura Perez and Stephan Trüeb
2200Assumption Result applies to buildings older than the value in the Age column.
3251
4301
5501
61001
710001

+ Show code

Popularity of renovation types(%)
ObsRenovationFractionDescription
1None0
2Windows65
3Technical systems30
4Sheath reform5
5General0

+ Show code

Locations of city areas

Locations of city areas (hidden for readability).



Data not used

This contains data that was not used in the model's calculations. This includes renovation rates, the rates of heat flowing out of buildings and total floor areas of multiple types of buildings in Helsinki. The floor area data is also found in the background data of this page, which was used in the model.

Effective floor area of buildings by building type.
Building Baseline 2020 2025 2050 Year of baseline Description
Residential 27884795 32472388 34890241 44069914 2014 Building stock of Helsinki area, 2014
Public 4537025 4764475 4945952 5855546 2014 Building stock of Helsinki area, 2014
Industrial 3277271 3306063 3360467 3640854 2014 Building stock of Helsinki area, 2014
Other 10861972 11406505 11840973 13806423 2014 Building stock of Helsinki area, 2014
Notes
  • Estimates were based on Siemens City Performance toolin seuraava kokous 2.2 and some derived calculations on BUILDING STOCK CALCULATION 2015.
  • How to get the numbers for the baseline floor area for residential, public, industrial and other: Residential floor area was named as residential together, public by summing the floor area of health care, education and common buildings, industrial buildings were as such and other buildings comprise of business, traffic, office and storage buildings.
  • Ref. Helsinki master plan for 2050: there are 860 000 citizens living in Helsinki (ref. www.yleiskaava.fi, visio2050); Residental buildings => fast growth
  • Prediction of citizen number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
  • Helsinki’s climate policy: 30% reduction in emissions: In 2010 the proportion of jobs in services and public sectors was 94%, and in industry 6%. In 2020 the proportion of jobs in services and public sectors is estimated to be 96%, and in industry 4%. Public and other buildings => between fast growth option and basic option, Industry=> Basic option
  • Prediction of job number in Helsinki in 2020, 2030, 2040 and 2050 was used for calculations (ref. Helsingin 30% päästövähennysselvitys).
  • Tables one and two The presentation of Tables 1 and 2


Technical notes:

Sheet 4_Input Buildings (Area Demand). Priority 1. Auxiliaries PPT. Absolute increase/decrease rate will be based on the inhabitants projected in time.
This is another list building types that was considered but rejected as too complex: Residential buildings, Government & public administration buildings, Commercial offices buildings, Data centers buildings, Education and K12 and universitiy buildings, Hospitals and healthcare buildings, Hotels and hospitality and leisure buildings, Exhibitions and fairs and halls buildings, Retail and stores and shops buildings, Warehouses & shopping mall buildings, Industrial buildings, Non residential buildings unspecified.
  • There was a problem with missing data. There is more than 400000 m^2 floor area that is missing; this is estimated from total area that is available for these buildings. For other buildings, there is more than 400000 m^2 total area missing from buildings where floor area is given. See statistical analysis [1]. This was corrected by inputation so that is floor area was missing, 0.8*total_area was used instead [2].
Renovations per year made in residental buildings owned by Helsinki city, by construction year of the buildings.[1]
Construction year Balcony glasses Windows Julkisivujen peruskorjaus Vesikattojen peruskojaus Lämmönvaihtimen uusiminen Patteriverkoston säätö Kylpyhuonekalusteiden vaihto Patteriventtiilien vaihto New balcony doors LTO-laitteen asennus Water consumption measurements
-20 0,0 % 1,1 % 1,1 % 1,1 % 1,1 % 1,1 % 1,1 % 1,1 % 1,1 % 1,1 % 1,1 %
21-25 0,0 % 10,3 % 1,2 % 11,1 % 10,3 % 10,3 % 1,2 % 10,3 % 1,2 % 10,3 % 10,3 %
26-30 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 9,5 % 0,0 %
31-35 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 % 0,0 %
36-40 0,0 % 0,0 % 0,0 % 0,0 % 4,2 % 4,2 % 0,0 % 0,0 % 0,0 % 4,2 % 0,0 %
41-45 0,0 % 16,7 % 0,0 % 16,7 % 16,7 % 16,7 % 0,0 % 16,7 % 0,0 % 16,7 % 16,7 %
46-50 0,0 % 5,2 % 0,0 % 7,4 % 7,4 % 7,4 % 0,0 % 7,4 % 0,0 % 5,2 % 5,2 %
51-55 0,0 % 11,3 % 0,0 % 8,8 % 8,8 % 8,8 % 0,0 % 8,8 % 0,0 % 8,8 % 16,2 %
56-60 0,0 % 5,4 % 0,0 % 4,9 % 6,2 % 7,1 % 0,0 % 6,2 % 4,5 % 4,5 % 5,4 %
61-65 0,0 % 1,5 % 1,3 % 0,8 % 2,9 % 2,4 % 1,0 % 2,4 % 0,9 % 0,9 % 2,9 %
66-70 0,6 % 2,9 % 1,2 % 2,8 % 1,4 % 2,3 % 1,1 % 1,1 % 0,1 % 1,1 % 1,1 %
71-75 3,2 % 3,1 % 3,4 % 2,9 % 3,1 % 2,6 % 0,2 % 1,1 % 0,2 % 0,2 % 0,2 %
76-80 0,1 % 2,7 % 0,1 % 0,7 % 2,0 % 1,7 % 1,1 % 1,2 % 0,2 % 0,4 % 0,2 %
81-85 1,0 % 2,8 % 0,7 % 2,3 % 3,3 % 4,8 % 3,5 % 0,0 % 0,0 % 0,0 % 0,8 %
86-90 0,0 % 1,3 % 0,0 % 2,1 % 6,1 % 1,6 % 0,7 % 1,8 % 0,3 % 0,3 % 1,0 %
91-95 0,6 % 0,3 % 0,0 % 3,9 % 8,6 % 1,9 % 5,1 % 0,8 % 0,2 % 0,0 % 1,3 %
96-00 0,1 % 0,0 % 0,0 % 0,6 % 1,2 % 1,0 % 1,5 % 1,0 % 0,0 % 0,0 % 4,2 %
01-05 2,9 % 0,0 % 0,0 % 0,0 % 1,2 % 1,0 % 0,0 % 1,0 % 0,0 % 0,0 % 0,7 %
06-10 1,7 % 0,0 % 0,0 % 0,0 % 0,5 % 0,5 % 0,0 % 0,5 % 0,0 % 0,0 % 0,0 %

# : In the document there are similar tables for total renovations from 2010 onwards to years 2016, 2020 and 2050. --Heta (talk) 09:28, 16 June 2015 (UTC)

Toimenpiteiden vaikutukset yksittäisessä kohteessa ja toimenpiteisiin liittyviä huomautuksia.[1]
Action The feature in question Difference to before Unit Notes
Glass for balconies U-value for windows -0,3 W/m2,K Säästö 1-4% rakennustasolla
Changing the windows U-value for windows -1 W/m2,K Vanhoista osa kaksilasisia ja osa kolmilasisia. Uudes 1,0 W/m2,K tai alle
Julkisivun peruskorjaus U-value of walls -0,2 W/m2,K U-arvo puolitetaan eli n. 100 mm lisäeristys
Vesikattojen peruskorjaus Yläpohjan U-arvo -0,15 W/m2,K Oletetaan 50% lisäeristys U-arvo puoleen eli n. 100 mm lisäerstys
Balcony door change U-value of doors -0,5 W/m2,K Tiivistyminen tuo lisäsäästöä
Thermal transmittances of building components and air flow rates. Averaged values calculates from the detailed model are presented here.[2]
Construction decade Thermal transmittance factors for building components (W/m2K) Ventilation and leakage air rates (1/h)
Floor Roof Walls Windows Outdoors Supply air through the heat recovery unit Supply air bypassing the heat recovery unit Leakage air
Before 1980 Single family house 0.52 0.32 0.54 2.14 1.18 0.30 0.05 0.20
Row house 0.52 0.36 0.56 2.15 1.00 0.3 0.05 0.20
Apartment building 0.59 0.37 0.61 2.18 1.40 0.37 0.00 0.10
1980's Single family house 0.30 0.21 0.28 1.70 1.00 0.30 0.05 0.15
Row house 0.32 0.22 0.30 1.70 1.00 0.30 0.05 0.15
Apartment building 0.34 0.23 0.29 1.80 1.40 0.35 0.00 0.10
1990's Single family house 0.25 0.20 0.25 1.70 1.00 0.30 0.05 0.15
Row house 0.32 0.22 0.28 1.70 1.00 0.30 0.05 0.15
Apartment building 0.332 0.22 0.28 1.75 1.40 0.38 0.00 0.10
2000's Single family house 0.24 0.17 0.24 1.40 1.00 0.30 0.05 0.13
Row house 0.28 0.18 0.26 1.50 1.00 0.45 0.05 0.15
Apartment building 0.28 0.18 0.26 1.50 1.40 0.55 0.00 0.10
2010's Single family house 0.16 0.09 0.17 1.00 1.00 0.30 0.05 0.10
Row house 0.16 0.09 0.17 1.00 1.00 0.50 0.05 0.15
Apartment building 0.16 0.09 0.17 1.00 1.00 0.60 0.00 0.10

See also

Helsinki energy decision 2015
In English
Assessment Main page | Helsinki energy decision options 2015
Helsinki data Building stock in Helsinki | Helsinki energy production | Helsinki energy consumption | Energy use of buildings | Emission factors for burning processes | Prices of fuels in heat production | External cost
Models Building model | Energy balance | Health impact assessment | Economic impacts
Related assessments Climate change policies in Helsinki | Climate change policies and health in Kuopio | Climate change policies in Basel
In Finnish
Yhteenveto Helsingin energiapäätös 2015 | Helsingin energiapäätöksen vaihtoehdot 2015 | Helsingin energiapäätökseen liittyviä arvoja | Helsingin energiapäätös 2015.pptx

References

  1. 1.0 1.1 HAESS Final report, Tampere University of Technology, 2010
  2. MK Mattinen, J Heljo, J Vihola, A Kurvinen, S Lehtoranta, A Nissinen: Modeling and visualisation of residential sector energy consumption and greenhouse gas emissions

Related files