Difference between revisions of "Intake fractions of PM"
From Testiwiki
(→References) |
(→Answer) |
||
Line 11: | Line 11: | ||
== Answer == | == Answer == | ||
− | <rcode name='answer' | + | {{attack|# |The answer should include data from [[Exposure to PM2.5 in Finland#Intake fractions of PM]].|--[[User:Jouni|Jouni]] ([[User talk:Jouni|talk]]) 17:16, 8 April 2015 (UTC)}} |
+ | |||
+ | <rcode name='answer' embed=1 graphics=1> | ||
library(OpasnetUtils) | library(OpasnetUtils) | ||
library(ggplot2) | library(ggplot2) |
Revision as of 17:16, 8 April 2015
This page is a variable.
The page identifier is Op_en5813 |
---|
Moderator:Jouni (see all) |
Give your opinion to the peer rating of the content of this page. |
Upload data
|
Contents
Question
What are intake fractions of airborne particulate matter for different emission sources and locations?
Answer
⇤# : The answer should include data from Exposure to PM2.5 in Finland#Intake fractions of PM. --Jouni (talk) 17:16, 8 April 2015 (UTC)
Rationale
Obs | Geographical area | Year | PM type | Source category | Subcategory | Result | Description of sub-category | Specification | Description |
---|---|---|---|---|---|---|---|---|---|
1 | Finland | 2000 | Anthropogenic PM2.5 | Power plants | Large power plants | 0.18-0.37 | Emission from large (>50 MW) power plants (n=117) | mode; min-max | Tainio et al. (2010): 0.28 (0.18-0.37) |
2 | Finland | 2000 | Anthropogenic PM2.5 | Power plants | Small power plants | 0.27-0.44 | Emission from small (<50 MW) power plants | mode; min-max | Tainio et al. (2010): 0.34 (0.27-0.44) |
3 | Northern Europe | - | Anthropogenic PM2.5 | Power plants | Major power plants | 0.50 | - | mean of all seasons | Tainio et al. (2009) |
Calculations
See also
Keywords
References
Related files
<mfanonymousfilelist></mfanonymousfilelist>