Energy use of buildings

From Testiwiki
Revision as of 19:48, 5 March 2014 by Jouni (talk | contribs) (Calculations for ovariables)
Jump to: navigation, search


Question

What is the use of energy of buildings?

Answer

Rationale

Energy efficiency in heating

Energy use by energy class of building(kWh/m2/a)
ObsEfficiencyHeatUser electricityWaterDescription
1Old15030Pöyry 2011 s.28
2New705040Pöyry 2011 s.32 (2010 SRMK)
3Low-energy355040Personal communication
4Passive17.5 - 255040Pöyry 2011 s.33; Personal communication


Energy efficiency of new buildings in the future(%)
ObsEfficiencyConstructedFractionDescription
1New2020-202910-20
2Low-energy2020-2029The rest of energy class
3Passive2020-202925-35
4New2030-20395-10
5Low-energy2030-203920-50
6Passive2030-2039The rest of energy class
7New2040-20490-5
8Low-energy2040-204910-30
9Passive2040-2049The rest of energy class
  • Old: old buildings to be renovated (or in need of renovation)
  • New: normal new buildings (no current need of renovation)
  • Low-energy: buildings consuming about half of the energy of a new building
  • Passive: buildings consuming a quarter or less of the energy of a new building
  • Chinese green building system: [4] [5]

Baseline energy consumption

--# : Note that below numbers are very preliminary (esp. electricity)! --Marjo 16:49, 13 March 2013 (EET)

# : There might be an error in the table: there is only district for non-residential buildings. Therefore they cancel out in the model. CHECK THIS BEFORE PUBLISHING RESULTS! --Jouni (talk) 22:47, 17 February 2014 (EET)

Baseline energy consumption per area unit(kWh/m2/a)
ObsBuildingHeatingHeatUser electricityTotal electricityYearDescription
1Detached housesDistrict134.7450184.742010Calculated from energy company´s data; Pöyry
2Detached housesElectricity130501802010Energiapolar; Pöyry
3Detached housesOil134.7450502010Pöyry. Efficiency 90-95% (energiatehokaskoti.fi).
4Detached housesWood134.7450502010Assumption. Efficiency of good kettles 80%(energiatehokaskoti.fi).
5Detached housesGeothermal4050902010Assumption
6Row housesDistrict168.8873.573.52010Calculated from energy company´s data
7Apartment housesDistrict172.3141.741.72010Calculated from energy company´s data
8CommercialDistrict161.82229.6229.62010Calculated from energy company´s data
9OfficesDistrict161.0793.193.12010Calculated from energy company´s data
10Health and social sectorDistrict214.97122.81122.812010Calculated from energy company´s data
11PublicDistrict165.47110.4110.42010Calculated from energy company´s data
12SportsDistrict121.3885.985.92010Calculated from energy company´s data
13EducationalDistrict170116.4116.42010Calculated from energy company´s data
14IndustrialDistrict168.44212.4212.42010Calculated from energy company´s data
15Leisure housesElectricity2.413.42010Calculated from energy company´s data
16OtherDistrict138.14170.3170.32010Calculated from energy company´s data
17Row housesElectricity15050Guesstimate
18Apartment housesOil15050Guesstimate
19OfficesOil15050Guesstimate
20EducationalOil15050Guesstimate
21IndustrialOil15050Guesstimate
22Non-residential buildings15050Guesstimate for Basel
23Special constructions15050Guesstimate for Basel
24Single-family houses15050Guesstimate for Basel
25Multiple-family houses15050Guesstimate for Basel
26Residential buildings with subsidiary use15050Guesstimate for Basel
27Buildings with partial residential use15050Guesstimate for Basel


Pöyry 2011. [1]

Energiapolar. [2]

Energiatehokaskoti.fi/Öljylämmitys [3]


--# : Note that below numbers are very preliminary (esp. electricity)! --Marjo 16:49, 13 March 2013 (EET)

Baseline energy consumption per volume unit(kWh/m3/a)
ObsBuildingHeatingHeatUser electricityYearDescription
1Detached housesDistrict42.1515.672010Calculated from energy company´s data; Energiapolar
2Detached housesElectricity40.6615.672010Energiapolar
3Detached housesOil42.1515.672010Energiapolar
4Detached housesWood42.1515.672010Assumption
5Detached housesGeothermal18.5615.672010Assumption
6Row housesDistrict53.2523.162010From energy company
7Apartment housesDistrict49.211.92010From energy company
8CommercialDistrict28.6540.642010From energy company
9OfficesDistrict36.3220.992010From energy company
10Health and social sectorDistrict55.231.532010From energy company
11PublicDistrict32.2121.492010From energy company
12SportsDistrict18.37132010From energy company; Electricity value comes from city´s renovation data
13EducationalDistrict40.2327.542010From energy company
14IndustrialDistrict30.5738.552010From energy company
15Leisure housesElectricity0.680.292010From energy company
16OtherDistrict29.8836.832010From energy company

Impact of renovations

Energy saving potential of different renovations(%,kWh/m2/a)
ObsEfficiencyBuilding2RenovationRelativeAbsoluteRenovation detailsDescription
1OldResidentialWindows1525New windows and doorsPöyry 2011
2OldResidentialTechnical systems5075New windows, sealing of building's sheath, improvement of building's technical systemsPöyry 2011
3OldResidentialSheath reform65100New windows, sealing of building's sheath, improvement of building's technical systems, significant reform of building's sheathPöyry 2011
4OldNon-residentialGeneral15-General renovationPöyry 2011
5OldNone00Renovation not done
6NewNone00Renovation not done
7Low-energyNone00Renovation not done
8PassiveNone00Renovation not done

Regulations regarding energy consumption of buildings

Maximum allowed energy consumption per unit (= E-value)(kWh/m2/a)
ObsBuildingYearE-valueDescription
1Detached houses2012 forward204Heated net area <120 m2; Finland´s Environmental Administration
2Row houses2012 forward150Finland´s Environmental Administration
3Apartment houses2012 forward130Finland´s Environmental Administration
4Shops and other commercial buildings2012 forward240Finland´s Environmental Administration
5Offices2012 forward170Finland´s Environmental Administration
6Health and social sector: Hospitals2012 forward450Finland´s Environmental Administration
7Health and social sector: Health care centers etc.2012 forward170Finland´s Environmental Administration
8Public2012 forward240Finland´s Environmental Administration
9Sports2012 forward170Does not apply to swimming- and ice halls; Finland´s Environmental Administration
10Educational2012 forward170Finland´s Environmental Administration
11Industrial2012 forward-E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration
12Leisure buildings2012 forward-E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration
13Other2012 forward-E-value must be calculated but there´s no limit for it; Finland´s Environmental Administration

Calculations for ovariables

+ Show code

See also

Keywords

References

  1. Pöyry 2011: Kuopion kasvihuonekaasupäästöjen vähentämismahdollisuudet v 2020 mennessä. [1]
  2. Energiapolar/Arvioi sähkönkulutus[2]
  3. Energiatehokaskoti.fi/Öljylämmitys[3]

Related files